Pump Static Head

Pump Static Head


Static head refers to the difference in elevation thus, the total static head of a system is the difference in elevation between the liquid levels at the discharge and suction points of the pump.

The static discharge head is the difference in elevation between the discharge liquid level and the pump centreline.

The static suction head on the other hand is the difference in elevation between the suction liquid level and the pump centreline.

If the static suction head has a negative value because the suction liquid level is below the pump centreline, it is often referred of as static suction lift.

If either the suction or discharge liquid level is under a pressure other than atmospheric, this pressure can be considered as part of the static head or separately as an addition to the static head.

 

There are occasionally situations that arise in which the determination of a pump duty pressure rise is not as straight-forward or at the very least, sometimes appears counter-intuitive.  Lets look at the following example case.



The system flow rate is 1000 USGPM and the system static head is 10 ft. There is also a 50 ft elevation change in the system downstream of the pump. The results of this system as modeled in FluidFlow are seen below.




As we can see, the pump duty pressure rise is 25.31 ft fluid (approx). The pump only needs to generate 25.31 ft head due to the syphon effects experienced in the system. This syphon effect helps reduce the required pump head when the system if filled with fluid as a result of hydrostatic pressure recovery as the liquid in the pipe drops in elevation and the pressure increases. It's this issue which often produces result you may not expect.


    • Related Articles

    • Negative Static Head on Pump Chart

      The starting point of the system resistance curve is dependent on the characteristics of the system and although you may not expect it, the system curve can start at a negative value on the head axis. This can occur in systems whereby the design ...
    • Centrifugal Pump Chart showing a Negative Static Head

      Negative Static Head: The starting point of the system resistance curve is dependent on the characteristics of the system and although you may not expect it, the system curve can start at a negative value on the head (y) axis. This can occur in ...
    • Reservoir/Tank Node & Negative Static Pressure

      When modeling a system with a reservoir or tan node at the outlet, it's important to note that the software will calculate the values for the supply pipeline based on the defined system operating conditions etc. We then need to review the results to ...
    • Static pressure below fluid vapor pressure or negative

      This message is often indicative of a data-entry issue and every step should be taken to correct this issue in order to obtain more accurate results. This warning can occur for a number of reasons as follows: 1. When a data-entry error/omission has ...
    • Pump Shaft Power

      The calculated "Duty Power" result for a pump in FluidFlow is the pump shaft power as opposed to pump hydraulic power. The image below provides an example pump shaft power calculation. Note, the "Duty Power" is only available as a result when we are ...