Modelling Submersible Pumps
When modelling a submersible pump which of course has no suction piping, it is necessary to insert a short section of pipework between the model inlet boundary and the pump suction connection. This is necessary to complete the model connectivity. The image below provides an illustration of such a design case where just 0.1m of "suction pipework" is included in the system. The pressure loss across this "suction pipework" is almost negligible relative to the losses across the other pipes and fittings in the system.
Related Articles
How do I model a submersible pump?
When modelling a submersible pump which of course has no suction piping, it is necessary to insert a short section of pipework between the model inlet boundary and the pump suction connection. This is necessary to complete the model connectivity. The ...
Vacuum Pumps
Vacuum pumps can be modeled in FluidFlow. Figure 1 gives an example of the performance data for a vacuum pump as supplied from a vendor. Figure 1: Vendor Vacuum Pump Performance Data. Figures 2 and 3 show this data defined in FluidFlow. You can see ...
Pumps in Parallel & Series
Pumps in Parallel Pumps are often installed in Parallel in systems which exhibit considerable variations in flow or when the system has variable flow requirements and when these requirements can be achieved by switching the parallel pumps on and off. ...
Viscosity Correction - Centrifugal Pumps
You can consider viscosity correction for centrifugal pumps in liquid flow systems by selecting: Options | Calculation | Global Settings as shown in Figure 1 below. Figure 1 You can turn this viscosity correction on/off from the INCLUSIONS option on ...
Modelling hoses
FluidFlow contains a "Flexible Smooth or Corrugated Hose" node as shown below. You can add various sizes or classifications if pipe to the database if you wish.