Fan/Blower Performance Curve (Performance Corrections Based on Operating Conditions)

Fan/Blower Performance Curve (Performance Corrections Based on Operating Conditions)


When entering a new fan or blower to the database, we must define if the reference gas volume flow units are based on STP (101325 Pa at 15oC) or NTP (101325 Pa at 0oC) conditions (Figure 1). When we then model the specific blower/fan in a system, FluidFlow automatically corrects the blower/fan performance based on actual flowing air density and pressure conditions.


Figure 1: Blower Performance Curve Referenced to STP.

Details of the performance curve are shown in Figure 2 below. 


Figure 2: Blower Performance Curve.

We have created a simple model with air as the fluid and the blower is the Radial Blower RB75 as shown above. Using a trial and error approach, we have adjusted the pressure and temperature conditions of the air at the system inlet (node 4) to arrive at a condition where we have a pressure of almost exactly 101325 Pa and 15oC (STP) at the inlet of the blower.


As we can see, the calculated actual duty flow rate is 736 m3/h. If we look at our original data entry for this fan above, we can see the curve has been defined at STP conditions which is almost identical to our actual operating scenario. Therefore, we can see that the duty flow calculated at STP conditions is 737 m3/h. The very slight difference can be attributed to the subtle difference in system pressure vs the specific 101325 Pa and 15oC condition.

If we were to adjust the actual flowing temperature or pressure conditions, we would get a different answer and the blower performance curve would be adjusted accordingly.


    • Related Articles

    • Database - Defining a Pump Capacity Curve

      When defining the pump capacity/performance curve for a pump in the database, the recommendation is to define the curve across the full quadrant. The image below shows two example approaches to defining a pump curve. The blue colored curve is ...
    • PSD Curve-Fit using d50 & d85 Particle Sizes

      A user intends to model a slurry however only has d50 and d85 particle sizes. The data has been entered as follows: The software includes a number of pressure loss correlations for slurry systems, some of which use just the d50 size, d50 & d85 sizes ...
    • Can FluidFlow predict two-phase choked flow conditions?

      There are no available correlations in the public domain for the reliable prediction of two-phase choked flow conditions. The software will solve the conservation of mass, energy and momentum and on this basis, if the model solves with a negative ...
    • Two-Phase Pipe Heat Transfer at Low Flow Conditions

      Let's consider a stainless steel pipe transporting saturated steam. The pipe inlet condition is 6 barg at 165 degrees C with a fixed flow rate at the outlet of the pipe 1 kg/h (0.0002778 kg/s). What we can sometimes see is that even if you set a low ...
    • Vacuum Pumps

      Vacuum pumps can be modeled in FluidFlow. Figure 1 gives an example of the performance data for a vacuum pump as supplied from a vendor. Figure 1: Vendor Vacuum Pump Performance Data. Figures 2 and 3 show this data defined in FluidFlow. You can see ...