Defined new fluid in database but can not find on input

Defined new fluid in database but can not find on input


The key point here is that, ALL physical properties for the new fluid must be defined in the database. If any rows are left as "undefined" the fluid won't be available to model in a system as all properties must be defined. 
 
Let's consider the fluid below. In this example, Diesel has been added to the fluids database however, the user hasn't entered data for viscosity. As we can see, viscosity is "undefined". This means this fluid won't be available to you if you attempt to assign the fluid to a model from a Known Pressure, Reservoir or Known Flow Boundary node. 

 

 
If however you complete the data-entry by defining in this case, the viscosity, the liquid light-bulb is then illuminated and the fluid will then be available to you if you attempt to assign the fluid to a model from a Known Pressure, Reservoir or Known Flow Boundary node. 
 

    • Related Articles

    • Troubleshooting Modeling of Fluid Mixtures

      A fluid mixture has been created in the Database and modeled in a single-pipe system as shown below. We can see that, when modeled, the results are suspect and we have a result of N/A for fluid phase state at the inlet and outlet of the pipe. This ...
    • Sprinkler Nozzle Input Data

      When we add a Sprinkler to the Boundaries database, we define the Sprinkler Min. and Max. Operating Pressures as shown below. When we then place a sprinkler node on the Flowsheet, we can define the Exit Pressure from the Input tab of the Data Palette ...
    • Database - Defining a Pump Capacity Curve

      When defining the pump capacity/performance curve for a pump in the database, the recommendation is to define the curve across the full quadrant. The image below shows two example approaches to defining a pump curve. The blue colored curve is ...
    • Database Fluids - Water and steam

      Steam is available in the database and is locked in the gas phase so no matter what temperature and pressure you model "steam", it will remain in its gaseous phase. This was a feature request by several users as they often use steam and add it to ...
    • K Value (Input K Value vs Calculated K Value)

      Why is the calculated K Value different to the K Value I have defined for the K Node? The difference arises from the change in density of the flowing fluid. Lets look at the example in the image below. The top model is a liquid flow system based on ...