Database - Defining a Pump Capacity Curve

Database - Defining a Pump Capacity Curve


When defining the pump capacity/performance curve for a pump in the database, the recommendation is to define the curve across the full quadrant. The image below shows two example approaches to defining a pump curve.

The blue colored curve is incomplete and depending on the number of data-points defined by the user, this type of curve-fit is possible. When solving a model, FluidFlow interprets flow rates past the inflection point of the curve which can then produce erroneous results in a model as well as lead to non-convergence. 

The recommendation is therefore to define the capacity/performance curve for a pump across the full quadrant. This can also speed-up model calculation, particularly in models with multiple pumps. 

The orange colored curve below therefore represents good practice and the approach which should be taken when adding any new pump curve to the database.

When adding your pump curve to the database, you can also set the Min and Max Limits (flow limits) to the values which relate to the vendor curve data. For instance, lets consider the curve data shown below. Let's say a vendor has provided a capacity curve between 5 m3/h and 40 m3/h. When defining the curve-data in FluidFlow, you can enter a data-point for 0 m3/h and 60 m3/h to complete the curve but in doing so, set the Min and Max Limits to 5 m3/h and 40 m3/h respectively.

This means that, if you were to model this pump in a system and the solved flow rate was below 5 m3/h, you would receive a warning message advising that the pump flow rate was below the minimum limit. Equally, if you were to model this pump in a system and the solved flow rate was above 40 m3/h, you would receive a warning message advising that the pump flow rate was greater than the maximum limit.

This therefore prompt us to review the pump performance more closely. 



    • Related Articles

    • Pump Shaft Power

      The calculated "Duty Power" result for a pump in FluidFlow is the pump shaft power as opposed to pump hydraulic power. The image below provides an example pump shaft power calculation. Note, the "Duty Power" is only available as a result when we are ...
    • Eductor / Ejector / Jet Pump

      At the moment, FluidFlow doesn't have an eductor node. There is however a workaround for this type of scenario as per the example below. Figure 1 shows a scenario where we have an eductor. Figure 1 A model of the above system has been developed in ...
    • PSD Curve-Fit using d50 & d85 Particle Sizes

      A user intends to model a slurry however only has d50 and d85 particle sizes. The data has been entered as follows: The software includes a number of pressure loss correlations for slurry systems, some of which use just the d50 size, d50 & d85 sizes ...
    • Fan/Blower Performance Curve (Performance Corrections Based on Operating Conditions)

      When entering a new fan or blower to the database, we must define if the reference gas volume flow units are based on STP (101325 Pa at 15oC) or NTP (101325 Pa at 0oC) conditions (Figure 1). When we then model the specific blower/fan in a system, ...
    • Negative Static Head on Pump Chart

      The starting point of the system resistance curve is dependent on the characteristics of the system and although you may not expect it, the system curve can start at a negative value on the head axis. This can occur in systems whereby the design ...